Norovirus (GⅡ) Qalabka lagu ogaado RT-PCR

Sharaxaad Gaaban:

Waxay ku habboon tahay in la ogaado Norovirus (GⅡ) ee kalluunka qolofleyda ah, khudaarta ceeriin iyo miraha, biyaha, saxarada, matagga iyo noocyo kale.


Faahfaahinta Alaabta

Tags Product

Magaca Alaabta

Norovirus (GⅡ) Qalabka lagu ogaado RT-PCR (Lyophilized)

Cabbirka

48tijaab/xirmo, 50tijaab/xirmo

Isticmaalka la damacsan yahay

Waxay ku habboon tahay in la ogaado Norovirus (GⅡ) ee kalluunka qolofleyda ah, khudaarta ceeriin iyo miraha, biyaha, saxarada, matagga iyo noocyo kale.Soo saarista aashitada nucleic-ka waa in lagu fuliyaa xirmada soo saarista aashitada nucleic ama habka pyrolysis tooska ah iyadoo loo eegayo noocyada kala duwan ee shaybaarka.Qorshaha waa ALL-DIYAAR PCR NIDAAMKA iyo baaritaanada looga baahan yahay ogaanshaha PCR fluorescent.

Nuxurka Alaabta

Qaybaha Xidhmada qeexid Walaxda
Norovirus (GⅡ) PCR Mix 1 × dhalo (budada Lyophilized)  50Tijaabi dNTPs, MgCl2, Aasaaska, Baadhitaanno, Dib-u-eegis Qoraal, Taq DNA polymerase
6 × 0.2ml 8 tuubo si fiican u dhuuban(Lyophilized) 48Tijaabi
Xakamaynta togan 1 * 0.2ml tuubo (lyophilized)  10Tijaabooyin

Plasmid ka kooban Norovirus (GⅡ) jajabyo gaar ah

Xalka kala dirida 1.5 ml Cryotube 500uL /
Xakamaynta taban 1.5 ml Cryotube 200uL 0.9% NaCl

Kaydinta & Nolosha shelf

(1) Qalabka waxa lagu rari karaa heerkulka qolka.

(2) Nolosha shelf waa 18 bilood at -20 ℃ iyo 12 bilood at 2 ℃ ~ 30 ℃.

(3) Fiiri calaamadda xirmada ku qoran taariikhda wax-soo-saarka iyo taariikhda uu dhacayo.

(4) Nooca budada lyophilized reagent waa in lagu kaydiyaa -20 ℃ ka dib kala diri iyo baraf soo noqnoqda -dhalaalaan waa in ay ahaataa wax ka yar 4 jeer.

Qalabka

GENECHECKER UF-150, UF-300 qalabka PCR ee wakhtiga-dhabta ah fluorescence.

Shaxda hawlgalka

a) Nooca dhalada:

1

b) 8 nooca tubbada si fiican loo jaro:

2

Kordhinta PCr

lagu taliyayDejinta

Talaabada Wareegto Heerkulka (℃) Waqtiga Kanaalka fluorescence
1 1 50 8 daq  
2 1 95 2 daqiiqo  
3 40 95 5s  
60 10s Ururi foornada FAM

* Fiiro gaar ah: Calaamadaha kanaalada Fluorescence ee FAM waxaa lagu soo ururin doonaa 60 ℃.

Turjumaada Natiijooyinka Imtixaanka

Kanaalka

Fasiraadda natiijooyinka

FAM Channel

Ct≤35

Norovirus (GⅡ) Wanaagsan

Undet

Norovirus (GⅡ) Negative

35

Natiijada shakiga leh, dib u tijaabi*

*Haddii natiijada ku celiska ah ee kanaalka FAM leedahay Ct qiimaha ≤40 oo ay muujiso "S" qaab qalooca caadiga ah, natiijadu waxa loo fasiraa mid togan, haddii kale waa taban.


  • Hore:
  • Xiga:

  • Alaabooyinka La Xiriira